GeneratorX Pro can be run in standalone mode, which means you can run programs without connecting to a computer. Follow the steps below to learn how to use GeneratorX Pro in standalone mode.

Step 1: Load programs into GeneratorX Pro

Firstly, complete the hardware connection and open Spooky2 GeneratorX Pro.

Open Spooky2 software. Go to the Control tab, and you will find two generators that have been detected.

Go to the Preset tab, and choose one Shell (Empty) Preset based on your need. For example, l will choose Healing (R) – JW to help with my bone.

Note: For choosing which shell preset to run, you can refer to this blog: https://www.spooky2-mall.com/blog/how-to-distinguish-healing-and-killing-frequency/

Then, go to the Program tab, search the keyword “bone”, and you will find many related programs. Double click or click the “+” button on the programs you want to load. You will see these programs have been added into “Loaded Program” in the lower-left corner. Before you proceed to the next step, check again whether these programs are exactly what you want.

Go to the Control tab, select “Overwrite Generator”. Choose either of the two generators on your GeneratorX Pro. It does not matter if you select generator #3 or generator #4. They both share the same programs. In this example, l will choose generator #3.

Click “Load GX”, you will see a new window pop up.

Below “New Program Name”, give the new program a name so that you can remind yourself what this program is about. If not, it will automatically combine all your program names as titles. Here, l name the program “Bone problems”. Double click on the location you want the program to be stored. You can overwrite an existing program if you like. There are 30 locations which you can store your programs. However, all of these programs should be within the limits of 200 frequencies. Here, l will place them in Location 16.

Now press Save. The “Load Generator box” will close, and the changes will be sent to your GeneratorX Pro. Repeat the above operations, you can download up to 30 programs into one GX Pro.

Step 2: Run programs in standalone mode

After the download is complete, close the Spooky2 software and disconnect GeneratorX Pro from your computer.

Connect Spooky2 Boost and Remote to one generator of your GeneratorX Pro. And then put your DNA sample into Remote.

Press “G1” or “G2” button, and you will see all the programs that have loaded into your GeneratorX Pro.

Use “Up” or “Down” button to select the program you want to run. Here, l will choose “Bone problem”.

Press “Start” button, and you will see that the program is ready on G1.

Then press “Loop” button. “Running” means that the program is running now.

Now, this program will run 24/7 until you stop it manually.

To watch the full instructional video, please click here:

There are some points you need to notice:

  1. Each program is limited to 200 frequencies. Inside one program, each frequency will be using the same waveform, amplitude, offset and duration (dwell).
  2. If you want to run a sweep, make colloidal silver or biofeedback scan, you should keep your computer connected.
  3. The Out 2 signal will be the inverse of Out 1. You cannot use Out 2 for modulation with Spooky2 Central or Spooky2 Plasma. However, special presets are available which allow these machines to run using Out 1.
  4. When you are connecting Plasma to a standalone GeneratorX, it works well for frequencies over 100,000 Hz. For lower frequencies, they get promoted to a harmonic over 100 kHz. Therefore, it is better to use online GX for plasma if you have frequencies under 100 kHz.

If you have any questions about this blog, welcome to leave a message in the comment area below!

Share this:

18 Comments

  1. Thank you! I am a brand new user and this is very easy to understand and follow.

    1. Hi, thanks for your supoort and affirmation. Our pleasure to help you learn better about our Spooky2. Any other questions, please feel free to send them to support@spooky2-mall.com, our support team is willing to help you at any time:)

      1. My software shows all the buttons underneath the Special Functions as dimmed and unusable. What can I do to rectify this?

        1. Hi, Keith. The above buttons are only useful when the generator is not connected to the computer and is in stand-alone mode.

  2. Question: How can I delete or overwrite program(s) on the GeneratorX PRO when the maximum amount – of stand alone programs on the GeneratorX PRO – reached the maximum of 30 programs?
    Note! I tried to overwrite / upload the 31th programe with Load GX to the GeneratorX PRO and it does not upload it.

    1. Dear Nat, here is a video on how to delete programs from Spooky2 GeneratorX: https://www.youtube.com/watch?v=aSoUAM5PBNk. Hope this helps. Any questions, feel free to contact us via email: support@spooky2-mall.com.

  3. Hi, I am already midway through the Terrain detox, currently at 7. Parasites and Liver Function. I’m using the GeneratorX Pro with my laptop connected, however I’d like to change it so that it only runs from my GeneratorX Pro as standalone, how do I go about doing this as I’m midway through?
    Thank you

    1. Dear Anne, you can load single preset that you have not yet run to your GeneratorX Pro, and here is a blog about how to load it to your generator: https://www.spooky2-mall.com/blog/how-to-load-and-run-terrain-protocol-using-generatorx/. Hope it helps. Any questions, feel free to contact us via email: support@spooky2-mall.com. Our customer service will help you to answer your questions.

  4. Should the led light on the remote needs to be on to show that it’s working?

    1. Dear Alan Tan,

      Thank you for your question! The LED light on the Spooky2 Remote does not necessarily need to be on for the remote to be working correctly. The behavior of the LED lights depends on the frequency, amplitude, and waveform being used in your program.

      In some cases, particularly with higher frequencies or certain settings, the LEDs may not visibly light up, even though the remote is still effectively transmitting the intended frequencies. You can check the program details or do a signal test to ensure the generator and remote are functioning as expected.

      If you need further assistance, please contact Spooky2 support at support@spooky2-mall.com.

  5. I appreciate that you have made the Rife frequency list available and easy to find. However, the popup link promoting the download constantly pops up over other site content and it interferes with site interaction and navigation. Perhaps you could add a “Don’t show this again” checkbox so users can opt out of the constant pop-up intrusion?

    1. Dear Kevin,

      Thank you for your feedback and for appreciating our Rife frequency list availability. We sincerely apologize for any inconvenience caused by the pop-up link on our website.

      Please note that our pop-ups are designed with an option to close them. If you have further insights or questions about Spooky2 products, please feel free to contact us at support@spooky2-mall.com. . We’re always here to assist!

      Thank you for your understanding!

      Warm regards,
      Spooky2 Team

  6. I created a program with a single frequency on channel 1 and the 11th harmonic on ch 2. When running stand-alone on the GenX Pro I only see the Ch1 on the display- unlike when running connected to the computer. Does this mean CH 2 is not running or just hidden in stand-alone mode? Thx

    1. Dear David,

      Thank you for your inquiry.
      Our support team will reach out to you shortly for further assistance.
      For any additional questions, feel free to contact our customer service team at support@spooky2-mall.com.

      Best regards,
      Spooky2 Support Team

  7. How do I run the terrain program on 3 people at the same time on Generator x pro. I have two boosts, and two reps remotes.

    1. Dear Nancy,

      Thank you for your question! Yes, it is possible to run the Terrain program on three people simultaneously using the GeneratorX Pro. To do this, wrap the DNA samples of each individual separately with stickers to keep them isolated.

      Feel free to reach out if you have any further questions or need assistance!

      Best regards,
      Spooky2 Support Team

  8. Hello I’ve followed all the instructions to run the program in standalone and using the loop function. However the generator is not running 24/7. Every time
    I come back to check the machine it has switched itself off.
    Thanks

    Natalie Saltman
    1. Hi, thanks for your message!

      If your GeneratorX is stopping in standalone mode, please check this common reason:

      It may be related to the schedule settings.
      Before disconnecting from the software, go to the Control tab and make sure the schedule is set to run 24/7. The default is from midnight to midnight. If the time on your generator is outside this range, it will stop running.

      Also, make sure to press Start first, then Loop, and the screen should say “Running.”

      If everything is set correctly and it still stops, feel free to contact us at support@spooky2-mall.com — we’ll be happy to help!

Leave a Reply

Your email address will not be published. Required fields are marked *

Mini Cart 0

Your cart is empty.